Merloni Elettrodomestici
GB 04-10-28/01 1-43Language Issue/Edition PageAll parts quoted in this do cument are the property of Merloni Elettrodomestici S.p.A. All rights reserved.
This document and the information it contains are supplied with out liability arising from possible errors or omissions. No part can be reproduced, used or copied without
written permission or a contractual clauseTechnical Manual
FULL NO FROST COMBINED UNIT (2003)
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 2-43Language Issue/Edition PageIndex
1 PRODUCT RANGE 3
1.1 Full No Frost Combined Models 3
1.2 Control panels / User interface 4
LEGENDS 5
LEGEND INDESIT NEW STYLING 2003 R EFRIGERATORS / COMBINED MODELS 7
Double door 7
Combined units 8
2 FUNCTIONING LOGICS 9
3 CHARACTERISTICS OF THE APPLIANCE 11
No Frost with display 11
No Frost Standard 35
4 ANALYZING THE LOADS 12
1. Compressor 12
2. Defrost Heating Elements 13
3. Freezer fan 16
4. Fridge fan 17
5. Fridge Lamps 18
6. Thermal fuses 19
7. Probes 20
8. Eeprom memory 25
9. Buzzer 26
10. Display (when present) 27
11. LEDs (when present) 28
12. Analysis of keys (models with display only) 29
13. Analysis of knobs and keys (STANDARD models only) 30
5 ELECTRONIC BOARDS 31
6 CONNECTION DIAGRAM 32
7 MAIN WIRING DIAGRAM 33
8 RECOMMENDED PROCEDURE FOR TE STING THE ELECTRONIC APPLIANCES 34
9 AUTOTEST 35
10 ALARMS 36
11 “DEMO MODE” FUNCTION (DISPLAY MODELS ONLY) 37
12 “ECO” FUNCTION 37
13 “HOLIDAY” FUNCTION 38
14 “SUPER FREEZE” FUNCTION 39
15 “SUPER COOL” FUNCTION 40
16 “ICE PARTY” FUNCTION (DISPLAY MODELS ONLY) 41
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 3-43Language Issue/Edition Page1 PRODUCT RANGE
1.1 Full No Frost Combined Models
Ariston width 60 Ariston width 60 Ariston width 70 Ariston width 70
Indesit width 60 Indesit width 60 Indesit width 70 Indesit width 70
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 4-43Language Issue/Edition Page1.2 Control panels / User interface
INDESIT
LED
ARISTON
LED
ARISTON
DISPLAY
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 5-43Language Issue/Edition PageLEGENDS
* Class
A / B1- Single mechanical compressor
2- Double mechanical compressor
3- Single electronic compressor
D- FIP Display
4- Display like evolution
Double
DoorLitres 1- White
2- Stainless steel
3- Bright silver
4- Yellow
5- Blue
6- Teak
7- Pearl Brown
8- Pearl White
9- Grey BlueNF No Frost
V Air
C Chiller
* If the class is lower than B, the class is not written in the description (MT 4511 NF TK).
LEGEND – ARISTON NEW STYLING MODELS L = 60 cm
MT Double door
MB CombinedMS Single-doorMU Vertical freezersMH Horizontal freezers
FIRST TWO NUMBERS
structure litres (same as old ones)
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 6-43Language Issue/Edition Page 3rd NUMBER
4th NUMBER
Other letters indicate performances1 1 Compressor
2 2 Compressors
3 1 Compressor + Solenoid valve
4 1 Compressor + Solenoid valve + Display + Air
D Display
1 White
2 Stainless steel
3 Bright silver
4 Yellow
5 Blue
6 Teak
8 White (French market only)
9 S/steel (French market only)
C Chiller
V Air
E Ever Fresh (Vacuum Kit)
BS Bacteria stop (Cell wi th Antimicrobic film)
NF Full No-Frost
EXAMPLE:
MTA 332 V
White EV+Display+AIRCombined330 litresAIR
Stainless steelEffic. class: “A”Double door
MBA 3841 C
380 litres
Chiller
Effic. class: “A”MT
MB 38 A4 1 CA3 32V
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 7-43Language Issue/Edition PageLEGEND INDESIT NEW STYLING 2003 REFRIGERATORS /
COMBINED MODELS
Double door
T Top freezer
A / A+ Efficiency class A
E Evolution
1st number2 = 290 litres
3 = 340 litres4 = 400 litres
ColourT = Teak
B = Blue
Y = Yellow
S = Silver
X = S/steel
Refrigerant gas I = Isobutane
Intended markets(FR) = France
(SP) = Spain
Etc.
Accessories /
Operation typeP = Playzone
C = Chiller
L = De luxe / Lock
E = External Handle
V = Ventilated
H = External Handle + Playzone
NF = Partial No Frost
FNF = Full No Frost
G = Glass (Glass refrigerator shelves)
Double door
T340 litres
TA3PX (FR)
Efficiency class Playzone FranceStainless steel
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 8-43Language Issue/Edition PageCombined units
B Bottom freezer
A / A+ Efficiency class A
E Evolution
1st number1 = 1 compressor
3 = 1 compressor + EV or
1 compressor + electronic control
2nd number
(3rd not compulsory)2 = 330 litres
3 = 380 litres
39 = 390 litres
4 = 400 litres
Combined
B380 litres
E13P S
Evolution France Playzone
Exception FNF SP:
Play Zone and Chiller are implied
(therefore in the descripti on, “PC” are not given).(FR)
Silver1 compressor
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 9-43Language Issue/Edition Page2 FUNCTIONING LOGICS
The refrigeration system consists of a compresso r, a condenser on the rear wall of the
appliance and an evaporator coil loc ated in the freezer compartment. The cold
produced by the evaporator coil reaches th e freezer compartment by means of the
freezer fan, and reac hes the refrigerator compartment by the delivery ducting and the
refrigerator fan and is distributed in the various shelves through the multiflow.
The refrigerator compartment temperature can be adjusted separately from that of
the freezer, and vice versa. It is not possible to swit ch off just one of the two
compartments; the only action possible is to switch off the entire appliance (refrigerator
and freezer) by means of the ON/OFF key on appliances with display, and using
the freezer knob for appliances with knobs.
The freezer compartment temperature adjust ment is managed by the electronic board
which receives the temperature values measure d by the freezer air sensor. The freezer
fan is fed, or not fed, ac cording to these values. The temperatures used to manage
demands for refrigeration from the freezer compartment and subsequent switching on
of the compressor depend on the settings fixe d by means of the user interface and
which determine a compressor switching on/off threshold.
Also the refrigerator temperatu re adjustment is managed by the electronic board which
switches the compressor and t he refrigerator and freezer fa ns on/off according to the
temperatures measured by t he refrigerator air sensor. The temperatures used to manage
demands for refrigeration from the refrig erator compartment and subsequent switching
on of the compressor and the two fans depend on the settings fixed by means of the
user interface.
CONDENSATION
RUN-OFF HOT AIR
RETURN
COLD AIR
DELIVERY
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 10-43Language Issue/Edition PageParticular situations
Optimizing consumption
Temperature adjustment follows different ru les if the followin g conditions occur:
ECO function On Temperature (ambient) measured by the s ensor on the electronic board of between
25 and 35 °C
Time elapsed from last door opening more than 22 hours
Duration of last compressor On cycle less than 45 min
The previous conditions are tested whenever t he compressor is switched off. If all these
conditions have occurred, with every dema nd for refrigeration by one compartment,
also the other compartment is forced to demand refrigeration (thus offering energy
saving, as the compressor is switched on le ss often), considering as switching Off
thresholds those set by the user.
This particular situation can be exited if at least one of the previous conditions has not
occurred again on switching off of the compr essor, or if the situation continues for
more than 255 days .
After a defrost
After every defrost, a refrigeration demand from the freezer compartment is forced,
without waiting for the freezer air sensor to detect a hotter value than the switching
on temperature relevant to the adjustment set by the user . The end of the demand
is managed following the classic rules of thermostatting.Set
temperatureFreezer
switching on
temperatureFreezer
switching off
temperatureSet
temperatureRefrigerator
switching on
temperatureRefrigerator
switching off
temperature
-18 °C -18 °C -22 °C 8 14 °C 12 °C
-18 °C -19 °C -22 °C 7 10 °C 8° C
-19 °C -22 °C -23 °C 6 8° C 7.5 °C
-20 °C -22 °C -25 °C 5 7° C 6° C
-21 °C -23 °C -26 °C 4 5° C 4° C
-22 °C -24 °C -27 °C 3 4° C 3.5 °C
-23 °C -25 °C -28 °C 2 2° C 1° C
-24 °C -26 °C -29 °C
-25 °C -27 °C -30 °C
-26 °C -27 °C -31 °C
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 11-43Language Issue/Edition Page3 CHARACTERISTICS OF THE APPLIANCE
No Frost with display Standard No Frost
User
interface
Input-OutputOn FR door:
6 Keys: (1) ON/OFF for switching the
appliance on and off; (2) ECO for
activation/deactivation of the ECO
function; (3) RESET ALARM for resetting alarm conditions; (4) MODE,
(5) ADJUST SELECT + and
(6) ADJUST SELECT – for shifting on the display1 Display: for adjusting the freezer (FZ)
and fridge (FR), setting the various
functions and signalling for the user1 Buzzer: on electronic board housed in
the control panelOn appliance instrument panel:
1 FZ Knob: (1) ON/OFF for switching
the appliance on and off and for freezer (FZ) adjustment
1 FR Knob: for adjusting the fridge (FR)
and activation/deactivation of HOLIDAY function1 Key SUPER FREEZE: for switching
on the SUPER FREEZE function
1 Key SUPER FRIDGE: for switching
on the SUPER FRIFGE function
3 LEDs: green for line, right yellow for
SUPER FREEZE function, left yellow for SUPER COOL function
1 Buzzer: on electronic board housed in
the control panel
Loads1 COMPRESSOR2 FR LAMPS (on Multiflow shell)4 DEFROST HEATING ELEMENTS
in parallel (evaporator, drip tray, chamber
division, elbow)1 FZ NF FAN (in FZ cell)1 FR FAN (in FR cell)
2 THERMAL FUSES1 COMPRESSOR
2 FR LAMPS (on Multiflow shell)4 DEFROST HEATING ELEMENTS
in parallel (evaporator, drip tray, chamber
division, elbow)1 FZ FAN (in FZ cell)1 FR FAN (in FR cell)
2 THERMAL FUSES
Sensors1 FZ EV SENSOR (in contact with FZ evaporator)
1 FZ AIR SENSOR (inside FZ compartment)
1 FR AIR SENSOR (inside FR
compartment)1 FR DOOR SWITCH (magnetic reed on
board behind control panel) 1 FZ EV SENSOR
(in contact with FZ evaporator)
1 FZ AIR SENSOR (inside FZ compartment)
1 FR AIR SENSOR (inside FR
compartment)1 FR DOOR SWITCH (magnetic reed on
board behind control panel)
Internal
serial lineBetween the two boards: passage on FR
door hinge Not Available
External
serial lineOutput in the compressor bay Output in the compressor bay
Memory
EEPROMOn electronic board On electronic board
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 12-43Language Issue/Edition Page4 ANALYZING THE LOADS
1. Compressor
The compressor, managed by the electronic board, is normally on when at least one of
the two compartments demands re frigeration, i.e., when the temperatures of the freezer
and/or refrigerator air sensor are such as to activate at least one refrigeration demand.
When both compartments no longer need refrig eration, the refrigeration demands are
deactivated and the compressor is switched off.
There are particular situations when, de spite demands for re frigeration by the
appliance's compartments, the com pressor remains switched off.
Compressor protection: in particular th e compressor switches on 8 minutes after
it has been switched off. This allows the gas pressures inside the thermodynamic
circuit to equalize w ithout risk of the compressor bec oming blocked due to too high
pressures inside the thermodynamic circuit.
Long periods of activity: if the compressor remains on for more than 4 hours it is
switched off, even if the compa rtments demand refrigeration.
Pause after defrost: at the end of every defrost, the compressor observes
10 minutes of protection so that the water formed can completely run off before
the evaporator starts to cool again.
POSSIBLE CAUSE OF MALFUNCTION:
Electronic board management
Compressor control circuit on the board
Connection on the boardWiring harnessConnection on the compressor
Breakages/anomalies inside the compressor
Temperature sensors open or short-circuited
TESTING:
General on appliance: force the compressor to switch on by activating the
24h SUPER FREEZE function and check th at the compressor switches on.
(Remember the 8 minutes of compressor protection).
Wiring: check for continuity and short circuits; check the connections (connectors and
terminals); check whether voltage is available.
Component: check that the component is fed; direct check of the compressor
(powered directly).
Electronic board: carry out a quick visual check of the board (breakages or burnouts,
etc.); check by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 13-43Language Issue/Edition Page2. Defrost Heating Elements
The purpose of the evaporator heating element is to melt any ice on the evaporating
coil. The presence of ice is due to t he condensation of moist air in the two
compartments, when it comes into contact with the low temperatures on theevaporator. This ice compr omises the heat exchange between the evaporator and the
air, reducing the refr igeration properties in the two compartments of the appliance.
The drip tray heating element melts any bits of ice coming off the evaporator and
falling onto the drip tray, and also prevents blockage of the pipe that takes the waterfrom the drip tray to the drain pipe.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 14-43Language Issue/Edition PageThe elbow and chamber divi sion heating elements allow the elimination of ice
formed on those elements; such p laces are subjected to direct flows of cold air, that can
produce ice which prevents correct air circulation.
The four heating elements ar e connected in parallel and the electronic board controls
them at the same time during the defrost ph ase. When these heating elements are
switched on, the compressor is kept switched off by the board, even in case of demands
for refrigeration by at least one of the two compartments.
Inside view Rear view
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 15-43Language Issue/Edition PageThe start and end of the defr ost phase are controll ed by the electronic board, taking
into account:
Start of defrost
total compressor On time from last defrost (on average11 hours). In any case the
period between two defros ts will be: max. 30 hours, min. 8 hours.
duration of last defrost
number of door openings
End of defrost
reaching the temperature of approx. 15 °C on the evaporator and in any case
approx. 40 minutes after the start of defrost.
POSSIBLE CAUSE OF MALFUNCTION:
Board management
Heating elements control circuit on the board
Connection on the board
Wiring harnessThermal fusesConnection on heati ng elements
Heating elements
Drain hole blocked
TESTING:
General on appliance: carry out the check usin g the Autotest procedure.
Wiring: check for continuity and short circuits; check the connections (connectors and
terminals); check whether voltage is av ailable; check non-opening of thermal fuses;
Component: check that the component is fed; directly check the heating elements
(fed directly).
Board: carry out a quick visual check of t he board (breakages or burnouts, etc.);
check by means of replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 16-43Language Issue/Edition Page3. Freezer fan
The purpose of the freezer fan is to distrib ute the cold air, produced by the evaporator
coil, inside the freezer compartment; the fa n is located behind the evaporator coil.
Particular situations
w i t h Refrigerator Door open the freezer fan is no t operated, even if the
compressor is working, and is switched on again only w hen the refrigerator door is
closed.
after defrost , even if the compressor is on, in addition to the 5 minute delay the
fan will wait until the temperature (m easured by the freezer sensor) on the
evaporator is -17 °C before switching on .
POSSIBLE CAUSE OF MALFUNCTION:
Board management
Fan control circuit on the board
Connection on the board
Wiring harness
Fan connectionsFreezer fan
TESTING:General on appliance: carry out the check usin g the Autotest procedure.
Wiring: check for continuity and short circuits; check the connections (connectors and
terminals); check whether voltage is available.
Component: check that the component is fed; directly check the freezer fan
(fed directly with special wiring).
Board: carry out a quick visual check of t he board (breakages or burnouts, etc.);
check by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 17-43Language Issue/Edition Page4. Fridge fan
The purpose of the fridge fan is to take the cold from freezer compartment to the
inside of the refrigerator compartment. By means of special ducting it draws the cold
air from the freezer and distributes it in the refrigerator compartment through openings
on the multiflow. The fridge fan, located on the bottom of the compartment, ismanaged by the board.
When the refrigerator co mpartment demands refrigerati on, the compressor is fed and
the fridge fan is switched on after 1 minute . When the refrigerator compartment
demands more refrigeration, the fan is sw itched off, even if the compressor could
remain on due to a demand for refrig eration by the freezer compartment.
Particular situations
w i t h Refrigerator Door open the fridge fan is not fed, even if the compressor is
working, and will be switched on again only when the refrigerator door is closed.
The fridge fan can be on even if there is no demand for refrigeration by the
refrigerator compartment. In fact, if the refrigerator door has just been closed the
fan is switched on for 3 seconds to prevent the hot and moist air that just has
entered the refrigerator compartment from descending through the delivery ducting
and freezing on the evaporator.
after defrost: at the first switching on of the compressor after a defrost, in addition
to the 5 minute time delay for fan sw itching on, there is also a wait for the
evaporator coil to reach -17 °C .
POSSIBLE CAUSE OF MALFUNCTION:
Board management
Fan control circuit on the board
Connection on the board
Wiring harnessFan connections
TESTING:General on appliance: carry out the check usin g the Autotest procedure.
Wiring: check for continuity and short circuits; check the connections (connectors and
terminals); check whether voltage is available.
Component: check that the component is fed; directly check the fridge fan
(fed directly with special wiring).
Electronic board: carry out a quick visual check of the board (breakages or burnouts,
etc.); check by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 18-43Language Issue/Edition Page5. Fridge Lamps
Inside the multiflow there are two lamps used to illuminate the refrigerator
compartment. The lamps are connected in pa rallel, therefore the electronic board
controls them at the same time.
The lamps stay on when the refrigerator door is kept open in appliance On conditions,
i.e., as well as being conn ected to the electric grid, the appliance must have been
switched on by means of the ON/OFF key on the user interface for models with
display, or a position other than stop on the freezer knob for models with knobs.
The lamps are switched off when the door is closed.
Particular situations
Refrigerator Door: if the door is kept open for more than 2 minutes , the lamp is
not kept on continuously, but is switched on and off and regular intervals; if the
door remains open for 7 minutes or more, the frequency of flashing increases.
POSSIBLE CAUSE OF MALFUNCTION:
Board management
Refrigerator door circuit on the board
Lamp control circuit on the board
Connection on the boardWiring harness
Lamp connections
LampPresence of magnet on the refrigerator door
TESTING:
General on appliance: switch the appliance on, open the refrigerator d oor and visually
check that the lamps come on.
Wiring: check for continuity and short circuits; check the connections (connectors and
terminals); check whether voltage is available.
Component: visually check the lamp; direct check of the lamp (powered directly).
A possible cause of incorrect lamp functioning can be the absence or wrong position of
the magnet on the refrigerator door.
Electronic board: carry out a quick visual check of the board (breakages or burnouts,
etc.); check by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 19-43Language Issue/Edition Page6. Thermal fuses
Their function is to protec t the combined unit from temper ature increase s caused by
anomalous functioning of the heating elem ents, during the defrost phase. They are
placed in contact with evaporator.
If the temperature on the evaporator reaches 72 °C , the thermal fuses open , cutting off
the feed to all the heating elements. They mu st be replaced in order to restore normal
operation.
POSSIBLE CAUSE OF MALFUNCTION:
Thermal fuse connections
Wiring harness
Thermal fuses
TESTING:
General on appliance: force the defrost, drip tray , chamber division, and elbow
heating elements to switch on (by means of the Autotest procedure) and check their
correct operation (a malfunction is not necessarily due exclus ively to the thermal fuses:
see the paragraph relevant to these heating elements).
Wiring and component: check for continuity and short circuits; check the
connections (connectors and terminals).
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 20-43Language Issue/Edition Page7. Probes
These are temperature sensors able to as sociate measurements in degrees centigrade
with resistive values that are easily read and managed by the microprocessor on the
board.
T h e Refrigerator Air Sensor , located inside the compartment, allows the
temperature set by the user to be adjusted . It is managed by the electronic board and
the user controls its adjust ment. The appliance continues to function in the event of
a thermostat malfunct ion or short-circuit thanks to a timed thermostat run mode
managed by the electronic board. The sensor cannot be replaced. The “Autotest”
function will confirm a malfunction.
The Freezer Air Sensor , located inside the compartment allows the temperature to
be adjusted, signalling critical temperature thresholds to the board. It is managed by
the electronic board and the user controls its adjustment. In the event of a freezer
probe malfunction or shor t-circuit, freezer comp artment alarms will not
be signalled to the electroni c board. The freezer will continue to ensure efficient
freezing thanks to a timer run thermostat . Also this sensor cannot be replaced.
The “Autotest” function will confirm the malfunction.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 21-43Language Issue/Edition Page The Evaporator Sensor in contact with the evaporator is all-important for the
duration and conclusion of t he defrost phase. The elec tronic board processes the
signal. If the sensor is cut off or short-circuited, defros ting is carried out in any case,
though not according to th e temperature but the times imposed by the electronic
board. Like the other sensors, the ev aporator sensor cannot be replaced.
The “Autotest” function will confirm the malfunction.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 22-43Language Issue/Edition Page The Ambient Temperature Sensor , located on the electr onic board, measures the
temperature of the room wher e the combined unit is wo rking. This parameter is
important for optimizing consumption.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 23-43Language Issue/Edition PageTemperature
°CResistance
OhmTemperature
°CResistance
Ohm
50 973 -12 16497
45 1181 -13 17429
40 1493 -14 18420
35 1765 -15 19475
30 2176 -16 20596
25 2700 -17 21791
20 3360 -18 23063
15 4225 -19 24418
10 5348 -20 25862
9 5611 -21 27402
8 5888 -22 29045
7 6182 -23 30797
6 6491 -24 32668
5 6818 -25 34666
4 7164 -26 36800
3 7529 -27 39082
2 7916 -28 41521
1 8325 -29 44131
0 8758 -30 46921
-1 9216 -31 49910
-2 9701 -32 53111
-3 10215 -33 56541
-4 10759 -34 60218
-5 11337 -35 64161
-6 11949 -36 68393
-7 12598 -37 72932
-8 13288 -38 77808
-9 14019 -39 83046
-10 14795 -40 88577
-11 15620
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 24-43Language Issue/Edition PagePOSSIBLE CAUSE OF MALFUNCTION:
Board management
Monitoring circuit on the board
Connection on the board
Sensor wiring
TESTING:
General on appliance: carry out the check using the “Autotest” procedure;
Wiring and component: check for continuity and short circuits; check the
connections (connectors and terminals); check th at the resistive values correspond to
the values given by the manufacturer (heat the probe touching it with your hand where
possible and check the variation in the resistive value).
Board: carry out a quick visual check of the board (breakages or burnouts, etc.); check
by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 25-43Language Issue/Edition Page8. Eeprom memory
All the appliance functioning parameters are stored in side the Eeprom; incorrect
communication between microprocessor and mem ory can seriously affect appliance
operation and the user's adjustments.
The Eeprom is located on the electronic board.
POSSIBLE CAUSE OF MALFUNCTION:
Microprocessor management
Interchange circuit on the boardMemory
TESTING:
General on appliance: carry out the check usin g the Autotest procedure;
Board: carry out a quick visual check of t he board (breakages or burnouts, etc.);
check by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 26-43Language Issue/Edition Page9. Buzzer
Buzzer operation is closel y tied to the signalling and alarm functions.
The buzzer is soldered onto the po wer board on the instrument panel.
POSSIBLE CAUSE OF MALFUNCTION:
Microprocessor management
Control circuit on the boardBuzzer
TESTING:
General on the appliance and component: a quick check can be that (with the
appliance ON) of keeping the refrigerato r door open for more than three to four
minutes in order to force the door open alarm condition; checking that the buzzer
starts to sound and goes off si mply by closing the door (its failure to activate could also
be due to a malfunction of the magnetic reed on the board).
Board: carry out a quick visual check of t he board (breakages or burnouts, etc.);
check by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 27-43Language Issue/Edition Page10. Display (when present)
The display allows the user to check the st atus of the appliance and to receive this
information: the display is soldered onto the Display board on the refrigerator door.
POSSIBLE CAUSE OF MALFUNCTION:
Microprocessor management
Control circuit on the boardDisplay
Main board and Displa y board connection cable
TESTING:
General on appliance and component: with the appliance ON, check that the display
is switched on correctly according to s pecifications. Press the MODE key repeatedly
and check that different functions are sel ected each time (ref rigerator temperature
setting, freezer temperature setting; SUPER COOL; SUPER FREEZE; HOLIDAY;
ICE PARTY; setting time, date, language in or der); verify that the text scrolls properly
in the dedicated area.
Wiring: (between the two boards) check for cont inuity and short ci rcuits; check the
connections (connectors and terminals).
Board: carry out a quick visual check of the boa rd (breakages or burnouts, etc.); check
by using a replacement. It is recommended to also check the Power board.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 28-43Language Issue/Edition Page11. LEDs (when present)
The LEDs allows the user to check status of the appl iance and to receive this
information: the LEDs are soldered onto the Power board on the control panel.
POSSIBLE CAUSE OF MALFUNCTION:
Microprocessor management
Control circuit on the boardLEDs
TESTING:
General on appliance and component: the green power LED must always be On
when the appliance is fed; the right yellow SUPER FR EEZE LED must come on when
the relevant function is activated; t he left yellow SUPER COOL LED must come on
when the relevant function is activated. Force the events that light up the LEDs and
verify they light up.
Board: carry out a quick visual check of the boa rd (breakages or burnouts, etc.); check
by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 29-43Language Issue/Edition Page12. Analysis of keys (mod els with display only)
The keys allow the user to manage the appl iance: they are solder ed onto the Display
board on the freezer door.
POSSIBLE CAUSE OF MALFUNCTION:
Wiring between the two boards
Microcontrol ler management
Control circuit on the boardKeys
TESTING:
General on the appliance and component:
ON/OFF key: with the appliance ON, press and hold down the key for about two to
three seconds, checking that appliance goes OFF (indications on the display); Press and
hold down the key again, checking that the appliance switches ON and that the display
indicates this).
ECO key: with the appliance ON, press the key and check that the ECO icon is
activated on the display. Press the key ag ain and the icon must be deactivated.
RESET ALARM RESET key: with the appliance ON, hold the refrigerator door open
for more than three to four minutes in or der to force the door open alarm condition,
(indications on the display an d buzzer sounding); check that alarm signalling stops on
pressing the key.
MODE key: (display models only) with the applia nce ON, press the key repeatedly and
check that different functions are sel ected each time (SUPER COOL; SUPER
FREEZE; HOLIDAY; ICE PARTY; setting time, date, language in order).
ADJUST SELECT + and AD JUST SELECT – keys: with the appliance ON, press the
MODE key once to activate the refrigerato r temperature setting condition; check that
the flashing temperature va lue on the display increases by 1 degree each time ADJUST
SELECT + is presse d and decreases by 1 degree ea ch time ADJUST SELECT – is
pressed.
Wiring: (between the two boards) check for cont inuity and short ci rcuits; check the
connections (connectors and terminals).
Board: carry out a quick visual check of the boa rd (breakages or burnouts, etc.); check
by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 30-43Language Issue/Edition Page13. Analysis of knobs and ke ys (STANDARD models only)
The keys and knobs allow the user to manage the appliance : they are soldered onto the
board on the appliance control panel.
POSSIBLE CAUSE OF MALFUNCTION:
Microcontrol ler management
Control circuit on the boardKeysKnobs
TESTING:
General on the appliance and component:
FREEZER knob: turn the knob all the way anticlockwise and check that the appliance is
OFF, opening the refrigerator door and checking that the lamps do not come on.
REFRIGERATOR knob: after switching the appliance on, turning the freezer knob
clockwise, check that on turning the refrig erator knob all the way anticlockwise the
buzzer beeps twice, confirming activation of the HOLIDAY funct ion. Starting from
this latter position, turn the refrigerator kn ob clockwise, checking that the buzzer beeps
only once, confirming deactivation of the HOLIDAY function.
SUPER FREEZE key: with the appliance ON and t he HOLIDAY function not active,
press the key and check that the SUPER FR EEZE function is activated (left yellow
LED comes on).
SUPER FRIDGE key: with the appliance ON and the HOLIDAY function not active,
press the key and check that the SUPER COOL function is activated (right yellow LED
comes on).
Board: carry out a quick visual check of the boa rd (breakages or burnouts, etc.); check
by using a replacement.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 31-43Language Issue/Edition Page5 ELECTRONIC BOARDS
FR DOORNF COMBINED UNITS WITH DISPLAY
STANDARD NF COMBINED UNITSDISPLAY
BOARD
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 32-43Language Issue/Edition Page6 CONNECTION DIAGRAM
–- –- –- –- –- –- –––
–-
–-
–-
–-
–-
–- –- –- –––
––– –- –-
–- –- –- –-
––– –- –––
FREEZER FANMV2BLACK
BLUE
REF.R3BROWN-1
FREEZER FAN
4BLUE-3DUCT HEATING
ELEMENTR6
1
2
3
4EMA DI COLLEGAMENTO
2
1THERMAL FUSE4 2
24YELLOW
G/VMB
CONDENSATORES NCOMPR.COND.
LN
M B1
G/VNBMR1SE
RIAL
W
IRIN
GBMNR9FRIDGE LAMPCONTROL BOARD
1 3 5 7 11 12 661 2 11 7 5 3 19 8
WHITE
WHITE
WHITE4
3
2112R2BLUEYELLOW
WHITE WHITE
BLU
EBLU
E
BROWNBROWN1
2
3
4
5
6FREEZER EVAP.
FREEZER AIRFRIDGE AIREDGE CONNECTOR 6-PIN
81 010BLUE-4BLUE-5BLU
E-6
REF.REF.REF.
DRIP TRAY
HEATING
ELEMENT
COEVAPORATOR
HEATING
ELEMENTFRIDGE LAMP
BLUE
MULTIFLOW
HEATING
ELEMENT
CONTROL
PANEL RES.
MV1
FREEZER FAN
RE
D
BLUE-1
WHITE
THERMAL FUSE
BLUE-2
BLUE-2BLUE-7
BLACKBLACK
BROWN
BROWN
BROWN-3BROWN-2BRO
WN
-4
YELLOW-1
YELLOW-2
TF1
TF2
GOCC.RES.EVAP.RES.RES.DIV. MV
4
3
2
1 122 1
4 3 2 1123423
1
INTERNO FREEZERCONNESSIONIVISTA FRONTALEFRONT VIEW
CONNECTIONS
INSIDE FREEZER
TFFRONT VIEW
CONNECTIONS
INSIDE FREEZERFRONT VIEW
CONNECTIONS
INSIDE FREEZER
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 33-43Language Issue/Edition Page7 MAIN WIRING DIAGRAM
–––––-
––– –––––-
NL
ELETTRONICASCHEDALI
SND1
SND2
SND3SERIALE
C (*)COc
s mRHTF1
TF2FRMV
FZMVR 1
R 2
R 3R 4
R 5LIR 6
LEGEND
L = LINE
N = NEUTRALCO = COMPRESSORPTC = PTC RELAYRH = THERMAL RELAY
C(*) = START CONDENSER X CPS HIGH
EFFICIENCY
SND-1-2-3 = SENSORSTF = THERMAL FUSE
LI = FRIDGE LAMPMV FR/FZ = FRIDGE/FREEZER FANR1 = DRIP
TRAY HEATING ELEMENTR2 = EVAPORATOR HEATING ELEMENTR3 = CHAMBER DIVISION HEATING ELEMENTR4 = MULTIFLOW HEATING ELEMENT (when present)R5 = CONTROL PANEL RES. (when present)R6 = DUCT-ELBOW HEATING ELEMENTELECTRONIC
BOARDSERIAL
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 34-43Language Issue/Edition Page8 RECOMMENDED PROCEDURE FOR TESTING THE
ELECTRONIC APPLIANCES
? End of check
Repeat procedure
from the beginning
Repeat procedure
from the beginningAction
Action
(when possible)
Action
Repeat procedure
from the beginning
Action
Repeat procedure
from the beginningSTART
General
testing on the
appliance
?
Connections?
Special Conditions?
Anything else?KO
Testing
EEPROM
OK
Testing
the wiring harness and
the connections
OK
Testing
the
component
OK
Testing
the
board
OKIf there is no wiring
harness go on to the next check
If component on the
board: go on to thenext checkIf EEPROM is not installed
go on to the next checkKOOK
KO
KO
KO
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 35-43Language Issue/Edition Page9 AUTOTEST
This helps with a quick check of the loads, which otherwise are difficult to activate, as
well as of t he probes and the EEPROM memory.
N.B.: before using the Autotest it is advisable to check the correct operation of
the refrigerator lamps and the buzzer which are used for signalling possiblemalfunctions.
MODEL ACTIVATION DEACTIVATION CHECK RESPONSE
No Frost
DISPLAYAppliance OFF by
ON/OFF key
Press the ECO key
for more than 3s- 255s after activation
– When the appliance is
switched on again by
means of the
ON/OFF key
– Switching off the
power supplyFR lampsVisual check by operator (the lamp comes
on when the door is opened)
FR fan Check by operator
FZ fan Check by operator
Evaporator, drip tray, chamber division, elbow heating elements
Check by operator
Probes (active after 20s)FR lamp flashes if KO (short or open) +
messages
FR air sensor = SND AIR FRFZ air sensor = SND AIR FZFZ evaporator sensor = SND
EVA FZ
PCB sensor (ambient) = SND PCB
If no anomaly sensors and EEPROM
message “TEST OK”
EEPROMBuzzer sounds if KO + message EEPROM memory = EEPROM
If no anomaly sensors and EEPROM message “ TEST OK ”
FR lampsVisual check by operator (the lamp comes
on when the door is opened)
No Frost
STANDAR
DAppliance OFF by
FZ knob
Press the SUPER
FREEZE key for more than 3s- 255s after activation
– When the appliance is
switched on again by means of the FZ knob
– Switching off the
power supplyFR fan Operator's visual check
FZ fan Operator's visual check
Defrost, drip tray,
chamber division, elbow heating
elementsOperator's visual check
Probes
(active after 20s)FR lamp flashes if: KO (short or open) + LEDs flash
FR air sensor = SUPER COOL
LED
FZ air sensor = SUPER FREEZE
LED
FZ evaporator sensor= SUPER
FREEZE LED
PCB sensor (ambient) = LINE
LED
EEPROMBuzzer sounds if KO + LINE LED flashes
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 36-43Language Issue/Edition Page10 ALARMS
Al a r m Ma na g e me n t
The appliance can provide the user with information on operational malfunctions:
Refrigerator door open too long
High temperature inside Freezer compartment
The indications and procedures for exiting refrigerator door open alarm situations are
given in the table:
The indications and proce dures for exiting freezer com partment temperature alarm
situations are give n in the table:DISPLAY MODELS STANDARD MODELS
Conditions SignallingExiting the
alarm
conditionSignallingExiting the
alarm
condition
Door open > 2 minutesBuzzer, red alarm triangle,
“door open” scrolling textClose door, “RESET ALARM” keyBuzzer Close door
Door open > 4 minutesBuzzer, red alarm triangle, “door open” scrolling text,
REFRIGERATOR lamp flashesClose door,
“RESET ALARM” keyBuzzer, Refrigerator lamp
flashes Close door
Door open > 6 minutesBuzzer, red alarm triangle,
“door open” scrolling text, REFRIGERATOR lamp flashes fasterClose door, “RESET ALARM” keyBuzzer, Refrigerator lamp flashes faster
Close door
DISPLAY MODELS STANDARD MODELS
Conditions SignallingExiting the
alarm
conditionSignallingExiting the
alarm
condition
If the temperature measured by
the FZ air sensor is HIGHER THAN -6 °C and after 150 minutes the
temperature is above +1 °C,
alarm A1 occurs (if the
temperature is above +8° A2
occurs). If it remains between
+1 °C and -6 °C for 24 hours A1occursBuzzer, red alarm
triangle, scrolling
text on display- Pressing the “RESET ALARM”
key once switches off the buzzer,
but does not exit the alarm
situation.
– Press the “RESET ALARM” key
twice to exit the alarm situation.Buzzer, SUPER
FREEZE LED
(yellow) and
SUPER COOL LED (yellow) flashOperating the freezer knob, switch the
appliance off (OFF
position) and on again
If the temperature measured by the FZ air sensor is HIGHER THAN -6 °C and after 150 minutes the temperature is above +8 °C,
alarm A2 occurs . After 2 hours of
A1 without “RESET ALARM” being pressed A2 occurs.Buzzer, red alarm triangle, scrolling text on display- Press the “RESET ALARM” key
once to switch the buzzer off, but the alarm situation is not exited.
– Press the “RESET ALARM” key
twice to exit the alarm situation.Buzzer, SUPER
FREEZE LED
(yellow) flashes and SUPER COOL
LED (yellow) and
LINE LED (green)Operate the freezer
knob to switch the
appliance off (OFF position)
and on again
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 37-43Language Issue/Edition Page11 “DEMO MODE” FUNCTION (DISPLAY MODELS ONLY)
The DEMO MODE can be ac tivated by keeping the MODE, ADJUST SELECT +
and ADJUST SELECT – butt ons pressed at the same time for more than 3 seconds,
starting from an init ial appliance OFF condition.
Activating this function makes the user interface (display and keys) completely
accessible without controlling any load (compr essor, refrigerator, freezer fan, heating
elements), irrespective of t he status of the appliance. T he lamp status is controlled
according to refrigerator door opening. DEMO MODE ac tivated is shown by the
wording DEMO MODE ON appearing ev ery 30 seconds. The DEMO MODE can be
deactivated by keeping the MODE, ADJ UST SELECT + and ADJUST SELECT –
buttons pressed at the same time for more th an 3 seconds, starting from the appliance
OFF condition, and is signalle d by the words DEMO MODE OFF.
12 “ECO” FUNCTION
This function offers temperatures optimized for preserving foods with the lowest
permissible consumption.This function is activated to set a progra mmed cycle for keeping the refrigerator and
freezer compartments at a given temperature.
This function cannot be activated with the a ppliance on logic OFF, if one of the two
possible alarms conditions (A1 or A2) is active an d if the Holiday function is active.
For display models the functi on is activated by means of the button on the refrigerator
door display with its relevant signalling, and for the standard models by turning both
knobs to “e”; normally, the adjustment for ECO function correspond s to that used for
calculating consumption accord ing to European regulations . The function can be
deactivated by pressing the ECO or ON/OFF keys on the door display. Upon
deactivation, the signalling on the displ ay stops and the user adjustment prior to
activation of the ECO function which is also shown on the display in the area relevant
to the freezer compartment and fridge, becomes active again.If one of the two alarms conditions exists with the ECO function active, the latter
function is not deactivated, however the alarm status prevails, performing particular
cycles in the freezer; when the alarm is deactivated, the ECO function operates
normally again. The ECO function cannot be activated in the alarm condition.The SUPER FREEZE, SUPER COOL, HOLI DAY and ICE PARTY functions can be
activated, and thus acquire priority w ith respect to the ECO function: ECO is
reactivated when these functions are deactivated. In case of sensor (freezer air sensor)
breakage, the function is time managed. In case of a power failure while the ECO
function is activated, when the power comes on again it will react ivate automatically
with the same settings as before.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 38-43Language Issue/Edition Page13 “HOLIDAY” FUNCTION
This function offers temperatures optimized for preserving foods with the lowest
permissible consumption in case of mini mum use of the refrigerator compartment:
particularly in the case of medium-long hol idays when the freezer can remain full and
with the refrig erator empty.
This function is activated to set a cycle (r efrigerator switching On threshold 15 °C ,
refrigerator switching Off threshold 13 °C ; freezer switching On threshold -16 °C ,
freezer switching Off threshold -20 °C ) programmed for keepin g the refrigerator and
freezer compartments at given te mperatures that will also be shown on the display
(when present) in the area relevant to the freezer compartment and fridge.
The function cannot be activated with the appliance on logic OFF and if one of the two
possible alarm conditions (A1 or A2) is active.
For display models the function is activated by means of t he refrigerator door display
with its relevant signalling; for standard mod els, by turning the re frigerator knob all the
way anticlockwise – this event is signalled by the buzzer beeping twice. The function is
deactivated by means of the refrigerator d oor display or when the appliance is switched
off (ON/OFF key on the display). For stan dard model the function is deactivated by
positioning the refrigerator k nob outside the relevant lim it area. Upon deactivation, the
buzzer beeps once, confirming t he exiting of that function, and the adjustment set by
the user by means of the knobs is reactivated.
If one of the two alarm conditions (A1 or A2) exists with the HOLIDAY function
active, the HOLIDAY function is not deacti vated, however the alarm status prevails,
performing particular cycles in the freezer; when the alarm is deactivated the
HOLIDAY function operates normally agai n. The HOLIDAY function cannot be
activated in the alarm condition.
If the HOLIDAY function is active, the SUPER FREEZE and SUPER COOL functions
cannot be activated. If SUPER FREEZE or SUPER COOL are already active and the
HOLIDAY function is activated, SUPER FREEZE or SUPER COOL will be regularlycompleted and then the HOLIDAY function will start operating. If the HOLIDAYfunction is active, th e ICE PARTY function cannot be activated. If ICE PARTY is already
active and the HOLIDAY function is ac tivated, ICE PARTY will be terminated
immediately and the message to remove th e bottle will be signalled to the user.
In case of freezer or refrig erator air sensor br eakage, the function is time managed. In
case of a power failure wh ile the HOLIDAY function is activated, when the power
comes on again it will re activate automatically.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 39-43Language Issue/Edition Page14 “SUPER FREEZE” FUNCTION
This function allows all foods placed in the freezer to be frozen in the best possible way
(also for best preserving the qual ities of the frozen foods).
Activating this function forces the compressor to stay on co ntinuously in order to have
maximum freezing power for the freezer com partment. Two activation procedures are
possible for this function: the SUPER FREEZE 24h for freezing small quantities of
food with activation possible ju st before or even at the time of placing the food in the
compartment; the SUPER FREEZE 48h for free zing large quantities of food with
activation recommended 24h bef ore placing the food in the compartment for already
having lots of cold available and to be able to complete t he freezing with the second 24
hours of operation activated;
In the first case the function is ended after the 24h, or if the freezer air sensor measures
a temperature below 0 °C for 254 minutes . In the second case the function is ended
after the 48h.
If the SUPER FREEZE function is activated, there may be an immediate defrost if the
cumulated “compressor On” hours are more than 1 hour , otherwise the function
proceeds as specified.
Defrosts can occur during execution of the SUPER FREEZE function. In particular,
after the compresso r has been on for 11 hours , it is switched off and a defrost is done,
which ends with the conditions already se en for normal operation; at the end of this
defrost, the compressor is switched on ag ain to complete the remaining hours of
SUPER FREEZE function.
The SUPER FREEZE function can be activated in the appliance ON condition,
whereas it is never possible in that of appliance OFF. The SUPER FREEZE cannot be
activated if one of the two alarm conditions (A1 or A2) exists, or if the HOLIDAY
function is active.
If the SUPER FREEZE 24h function is activ ated by means of t he refrigerator door
display (when present), the icon on the disp lay remains on (fixed), whereas for the
SUPER FREEZE 48h function the same icon comes on flashing, indicating activation
and execution of the first 24h; after the fi rst 24h of activation the icon remains on
(fixed), indicating the start of the second 24h . The area on the disp lay relevant to the
freezer compartment continues to show th e temperature set by means of the user
adjustment, which will become active again only at the end of the SUPER FREEZE
function (irrespective of 24h or 48h).
For the standard models, on activating the fu nction by means of the special key on the
appliance control panel, the relevant LED remains on (fixed), whereas for the SUPER
FREEZE 48h function the same LED comes on flashing, indicating activation and
execution of the fi rst 24h; after the first 24h of activation the LED remains on (fixed),
indicating the start of the second 24h.
Switching the appliance off (ON/OFF key on the display) automatically involves
deactivation of the function. Activation of one of the two alarm modes (see paragraph“Alarm Management”) automatically involves deactivation of the function, if the alarmcondition is reset, the function is not reactivated.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 40-43Language Issue/Edition PageThe SUPER FREEZE function (ir respective of 24h or 48h) can be deactivated by a
further action on the display (or the special key, for standard models); another exit
mode is also reaching of t he max. activation temperature appraised for the function:
24h or 48h according to the mode acti vated. For the SUPER FREEZE 24h function
only, exiting is also provided for when a given temperature is reached in the freezer
(0 °C for 254 minutes). The latter exit mode is not considered in the event of freezer air
sensor breakage. Upon deactivation the sign alling on the display stops and the user
adjustment prior to activation of the SUPE R FREEZE function (irrespective of 24h or
48h) is reactivated. If one of the alarm cond itions exists, this prevails, interrupting
normal SUPER FREEZE operation and deactivating the function.
The ECO and HOLIDAY functions can be activated, but t hese start operating as soon
as the SUPER FREEZE function is deactivated (for any reason). The ICE PARTY can
be activated, which thus gains priority over the SUPER FREEZE function (overlapping
it): SUPER FREEZE reactivates (continuing the previously reached condition) when
the ICE PARTY function is deactivated. In the event of a power failure while theSUPER FREEZE 24h or 48h function is activ ated, when the power comes back on the
SUPER FREEZE 24h or 48h function is automatically reactivated, completing theremaining hours, unless a temperature alarm has not immediately occurred.
15 “SUPER COOL” FUNCTION
This function allows large quantities of food p laced in the refrigerat or to be chilled in
the best possible way.
Activation of this function changes the switching on and off thresholds for the
refrigerator compartme nt (switching off at 4° C switching on at 6° C) with an average
temperature of 2° C; these new thermostatting th resholds are maintained for 3 cycles .
The SUPER COOL function can be activated in the appliance ON condition, whereas
it is never possible in that of applia nce OFF. The SUPER COOL function cannot be
activated if one of the two alarm conditions exists (A1 or A2) or if the HOLIDAY
function is active.
If the SUPER COOL function is activated by means of the refrigerator door display
(when present), the icon on t he display remains on (fixed) for the entire time required
by the refrigerator to perfo rm the cycles with the new thresholds. The area on the
display relevant to the refrigerator compart ment continues to show the temperature set
by means of the user adjustment.
For standard models, activation occurs by me ans of a special key on the control panel,
the relevant LED remains on (f ixed) for the entire time requi red by the refrigerator to
perform the cycles with the new thresholds.
Switching the appliance off (ON/OFF key on the display) automatically involves
deactivation of the function. Entering one of the two alarms modes automatically
involves deactivation of t he function, if the alarm is reset, the function is not
reactivated.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 41-43Language Issue/Edition PageThe SUPER COOL function can be deactivated by a furthe r action on the display, or
by means of the special key in standard models; another exit mode is also the
completion of the number of cycles with the new thermostatting thresholds.
At the moment of deactivati on the signalling on the display stops and the user
adjustment prior to activation of the SUPE R COOL function is reactivated. If one of
the two alarms conditions ex ists it prevails, interrup ting the normal SUPER COOL
operation and deactivating the function.
The ECO and HOLIDAY functions can be activated, but t hese start operating as soon
as the SUPER COOL function is deactiva ted (for any reason ). The ICE PARTY
function can be activated, which thus g ains presence over the SUPER COOL function
(overlapping it).
In the event of a power failure while the SU PER COOL function is activated, when the
power comes back on, the SUPER COOL function is automatically reactivated,
completing the remaining cy cles, unless a temperature alarm has not immediately
occurred.
16 “ICE PARTY” FUNCTION (DISPLAY MODELS ONLY)
This function allows a bottle (champagne, wine, etc.) to be chilled in the shortest
possible time in the freezer compartment, with a signal from the appliance at the end of
the operation, thus avoiding breakage of the bo ttle due to freezing of the liquid inside it.
Activating this function forces the compressor to stay on co ntinuously in order to have
maximum freezing power for the freezer com partment and thus qui ckly chilling the
bottle. At the end of a given period, wh ich is about 30’ (considered optimum for
chilling the bottle), the appliance continues operating as it did bef ore activation of the
function and the display and bu zzer alert the user to remo ve the bottle (now suitably
cold) from the freezer. A further intermediate time , of approx. 20’, has been
identified, after which a signal indicates that the bottle is “cellar cool” + beep:
the user can decide to remo ve or continue chilling it) .
The ICE PARTY function can always be activated in the appliance ON condition,
whereas it is never possible in that of appliance OFF. The ICE PARTY function cannot
be activated if one of the two alarm conditions exists (A1 or A2) or if the HOLIDAY
function is active.
The function is activated by means of the re frigerator door display with its relevant
signalling. The area on the display relevant to the freezer compartment continues to
show the temperature set by means of t he user adjustment, which will become active
again only at the end of the ICE PARTY function.
Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)Technical Manual
GB 04-10-28/01 42-43Language Issue/Edition PageSwitching off the appliance (ON/OFF key on the display) automatically involves
deactivation of the function.
Entering one of two al arms modes automatically involves deactivation of the function;
the signalling (display and buzzer) fo r removing the bottle from the freezer
compartment is in any case activated.
Activation of the HOLIDAY function deact ivates the ICE PARTY function, activating
the relevant message to remove bottle, on the display.
The ICE PARTY function can be deactivate d by a further action on the display;
another exit mode is also reaching of the given time for the function. ( On reaching
half time the appliance activates an alert on the display with relevant sounding of the
buzzer, “cellar cool” + beep , for about 15 seconds: if the user wishes to remove the
bottle and force function de activation by pressing t he RESET ALARM key, the
function ends then, whereas if the user does not perform a ny action the operation
continues until the maximum preset temper ature is reached). At the moment of
deactivation the signalling on the display by means of the icon stops and the user
adjustment prior to activation of the ICE PA RTY function is reacti vated; the display
and buzzer signal that the bottle is suitably cold and th at it should be removed from the
freezer compartment so as not to damage it with addition al cold; this signalling stops
when the RESET ALARM is pressed. If one of the two alarms conditions exists it
prevails, interrupting the normal ICE PART Y operation and deacti vating the function;
the signalling (display and buzzer) fo r removing the bottle from the freezer
compartment is in any case activated.
The ECO and SUPER FREEZE fu nctions can be activated, but these start operating
as soon as the ICE PARTY function is deactivated (for any reason).
In the event of a power failure while the ICE PARTY function is activated, when
the power comes back on the function is not automatically reactivated, whereas
the signalling (display and buzzer) to remove the bottle from the freezer
compartment is immediately activated.
Merloni Elettrodomestici
GB 04-10-28/01 43-43Language Issue/Edition PageMerloni Elettrodomestici S.p.A.
47 Viale Aristide Merloni, Fabriano – 60044 – Italy
tel. 0732/6611 – telex 560196 – fax 0732/662954www.Merloni.com
All parts quoted in this do cument are the property of Merloni Elettrodomestici S.p.A. All rights reserved.
This document and the information it contains are supplied with out liability arising from possible errors or omissions. No part can be reproduced, used or copied without
written permission or a contractual clause.
Copyright Notice
© Licențiada.org respectă drepturile de proprietate intelectuală și așteaptă ca toți utilizatorii să facă același lucru. Dacă consideri că un conținut de pe site încalcă drepturile tale de autor, te rugăm să trimiți o notificare DMCA.
Acest articol: GB 04-10-28/01 1-43Language Issue/Edition PageAll parts quoted in this do cument are the property of Merloni Elettrodomestici S.p.A. All rights… [626097] (ID: 626097)
Dacă considerați că acest conținut vă încalcă drepturile de autor, vă rugăm să depuneți o cerere pe pagina noastră Copyright Takedown.